Product Residential
Plot No. 645-7562 @ Al ghurair Residence 5 Living Legend - Wadi Al Safa 3 - Dubai, Dubai, United Arab Emirates
Posted By: OSOOL ASSET MANAGEMENT SERVICES L.L.C
Supply and installation of Electrical Insulating Rubber Mat in the LV room, Site visit recommended.Material Spec: Natural Rubber, Anti-Slip, Fire resistant, Oil Resistant.
Break Down Residential
Dragon Views, International City, Dubai, United Arab Emirates
Posted By: HOAM- Highrise Owners Association Management
There is no physical barrier separating the children’s pool from the main swimming pool. Both pools are accessible from the same deck level without restriction. The depth difference creates a potential drowning hazard, as children can freely move into deeper water. No self-closing or self-latching gate system is install...
Break Down Mixed Use
Atlantic Tower, Dubai Marina, Dubai, United Arab Emirates
Posted By: HOAM- Highrise Owners Association Management
LEAK REPAIR OF VRF SYSTEM• L.O.T.O (Log Out Tag Out) the system • Check the parameters using LGMV • Perform leak test. • Identify & rectify the leak in the system. • Perform the required pressure test to ensure there is no further leak. • Flush the system to remove contaminants.  • Keep...
Break Down Mixed Use
Riviera Dreams, International City, Dubai, United Arab Emirates
Posted By: HOAM- Highrise Owners Association Management
The External Signage board 2 Nos required painting and lights of the signage board BOH need to be fixed.Scope of WorkSupply and installation of front-light 3D aluminum letters, including rainprooftransformer.* LED used: SamsungWall preparation and painting work* Remove old paint* Sanding and primer application* New paint usin...
Break Down Mixed Use
Hilliana Tower, Al Sofouh, Dubai, United Arab Emirates
Posted By: HOAM- Highrise Owners Association Management
Scope of Work: Replacing the façade glass to restore visibility and maintain the structural integrity and quality of the façade system.Approximately glass size – 110 cm * 90 cm
Break Down Mixed Use
Hilliana Tower, Al Sofouh, Dubai, United Arab Emirates
Posted By: HOAM- Highrise Owners Association Management
Scope of Work:Power socket damaged due to wear and tear. Power socket need to be replaced.Up Limit switch damaged due to electriacal failure and wear and tear. Limit switch need to be replaced.Pressure Roller damaged due to usage, wear and tear. Need to be replacedRope Guide damaged due to usage, wear and tear. Need to be rep...
Break Down Residential
Bermuda Views, Dubai Sports City, Dubai, United Arab Emirates
Posted By: HOAM- Highrise Owners Association Management
System Isolation and Preparation Isolate and depressurize the affected section of the pipeline system in accordance with site safety and operational procedures. Verify zero pressure before commencement of dismantling. Dismantling and Removal Remove existing 6-inch and 4-inch copper pipelines from the pump header con...
Break Down Mixed Use
Riviera Lakeview, International City, Dubai, United Arab Emirates
Posted By: HOAM- Highrise Owners Association Management
Scope of Work:Supply and Installation of Traction Sheave (L2, L3)Supply and Installation of Main Ropes (L2, L3)Emergency Landing Device Upgrade (L1, L2, L3)
Break Down Mixed Use
Hilliana Tower, Al Sofouh, Dubai, United Arab Emirates
Posted By: HOAM- Highrise Owners Association Management
Scope of Work:Roof top FAHU 1 & 2 and system 01 to 08 condensing unit findings rectification.Recommended to change the all the condensing unit wiring with necessary accessories make in operational in the Auto mode to avoid continuous running of FAHU.• Recommended to replaced damaged pipe line insulation in all unit.• FAHU...
Break Down Mixed Use
Hilliana Tower, Al Sofouh, Dubai, United Arab Emirates
Posted By: HOAM- Highrise Owners Association Management
Scope of Work:1. Fire Protection System – FM200 (Shield System) The contractor shall carry out the following works: Supply and install safety covers for all FM200 manual release switches. Refill HFC227EA gas in the FM200 system cylinders (45 kg capacity). Replace faulty 3” impulse valve discs. Perform complete testing...