Break Down
Residential
La Fontana Apartments, Arjaan, Dubai, United Arab Emirates
Posted By: HOAM- Highrise Owners Association Management
1.Mobilization of team, tools, and safety equipment2. Provision and installation of external scaffolding toaccess the pipe section between floors.3. Breaking and opening the affected wall areas,4. Cutting and removing the blocked section of thevertical drainage line.Supply and installation of new PVC drain pipe withproper fit...
Water leakages from transfer pump & booster Pump discharge line (JB004-26-00531)
Break Down
Residential
La Vista Residence 1, Dubai Silicon Oasis, Dubai, United Arab Emirates
Posted By: HOAM- Highrise Owners Association Management
Water leakages from transfer pump & booster pump discharge line.Need to replaced of all rusted parts in the transfer pump and booster pumpMaterials Details: • Transfer Pump: • (1 ½)- inch Gate Valve – 2 Nos • (1 ½ )- inch Nipple -2 Nos • NRV -2 Nos • Booster Pump: • (1)- inch Gate Valve - 2 ...
Mechanical Electrical Plumbing (MEP) Break Down (JB1099-26-00659)
Break Down
Mixed Use
Dubai Marina, Dubai, United Arab Emirates
Posted By: SG Community Management Services LLC
Dear
Service Provider,
Greetings
from Strata Global!
Kindly
arrange a site visit and send us your best proposal for Application of Fire
Rated silicon in Chilled water pipeline sleeves in Marina Arcade, located
in Dubai Marina, Dubai.
Scope
of Work:
Application of Fire Rated silicon in Chilled wat...
Break Down
Mixed Use
Goldcrest Views, Jumeirah Lakes Towers, Dubai, United Arab Emirates
Posted By: HOAM- Highrise Owners Association Management
Scope of Work – Chilled Water (CHW) Pipeline Insulation & Ceiling Restoration
1. General
The Contractor shall provide all labor, materials, tools, equipment, supervision, and consumables required for the replacement of chilled water (CHW) pipeline insulation in common areas of the building. All works shall be executed in ...
Gate Valve Leakage at B-1 Parking (JB004-26-00467)
Break Down
Residential
The Spirit, Dubai Sports City, Dubai, United Arab Emirates
Posted By: HOAM- Highrise Owners Association Management
Supply & installation of:2-inch Gate Valve Brass 1 QTY2-inch Male Adapter HPVC 2 QTYTeflon Tape – 10 nos 10 QTYTangent Solvent Glue 2 QTYClose the DEWA line gate valve by repairing or replacing the faulty components to ensure complete shut-off. Test the valve operation to confirm that water flow can be fully stopped. Once...
Transfer Pump Pipe Line Leak Rectification (JB004-26-00457)
Break Down
Mixed Use
Atlantic Tower, Dubai Marina, Dubai, United Arab Emirates
Posted By: HOAM- Highrise Owners Association Management
Supply & Installation of: HPVC Transfer Pump Pipe Line Repairing & Modification.HPVC 4” pipe line repairing and modification.Supply and replacement of new 4” HPVC pipe fittings.Making access for HPVC pipe line riser including cutting and removing of existing cement board.HPVC damaged pipe cutting and removing.Sup...
Break Down
Residential
La Vista Residence 2, Dubai Silicon Oasis, Dubai, United Arab Emirates
Posted By: HOAM- Highrise Owners Association Management
Scope of Work:Supply and install:1. Staircase Pressurization Fan Motor▪ 415V, 3-phase, 50Hz▪ Fire-rated duty, Insulation Class F/H▪ IP55 rating2. Smoke Extract Fan Motor▪ High-temperature rated (e.g., 250°C/2hr)Insulation Class H▪ 415V, 3-phase▪ IP55 or higher Testing and Commissioning:• Electrical termination, earthing,...
RECTIFICATION OF HOT WATER LEAKAGE (JB004-26-00227)
Break Down
Residential
The Diamond Tower, Dubai Sports City, Dubai, United Arab Emirates
Posted By: HOAM- Highrise Owners Association Management
Scope of Work – Hot Water Leak Rectification
Replacement of faulty gate valve and associated pipes in front of Apartment 1005.
Replacement of faulty PPR pipe, gate valve, and fittings, including ceiling repair and painting, in front of Apartment 609.
Replacement of PPR pipe and fittings in front of Apartment 209.
Apar...
Supply of MEP Spares (JB004-26-00203)
Break Down
Residential
The Spirit, Dubai Sports City, Dubai, United Arab Emirates
Posted By: HOAM- Highrise Owners Association Management
Scope of Work:Supply of MEP Spares:LED MR16 GU5.3 6.5W / 2700K (LEDVANCE) – 100 Nos
LED Tube FSL T8 18W / 865, 6500K (FSL) – 100 Nos
OSRAM Dulux Star 15W / 865 E27 Energy Saver – 40 Nos
RAK Ceramics WC Seat Cover – 05 Nos
½” Angle Valve – 05 Nos
Milano Deluxe Plus Hand Shattaf – 05 Nos
½” Garden Tap – 05 Nos