SHARED - Rectification of Life Safety System
Break DownJOB REFERENCE:
JB007-23-00706
S. No. |
Block |
Location |
System |
Description |
Unit |
Qty. |
3 |
Block-A |
Basement floor
Pump Room |
FACP |
Supply &
Replacement of
Heat Detector with Base |
nos. |
1 |
4 |
503 out side |
FACP |
Supply &
Replacement of
Sounder |
nos. |
1 |
|
5 |
Lift Lobby-1 |
FACP |
Supply
& Replacement of Smoke
Detector with Base |
nos. |
1 |
|
7 |
Common |
FE |
Supply &
Replacement of
Hose for Co2 5 kg Fire
Extinguisher |
nos. |
13 |
|
8 |
Common |
FE |
Refilling
of DCP 4.5 kg Fire
Extinguishers |
nos. |
3 |
|
9 |
Common |
FOAM |
Supply &
Replacement of
Level tube for Foam |
nos. |
1 |
|
10 |
Common |
FFS |
Tachometer
Sensor |
nos. |
1 |
|
11 |
Common |
FFS |
Gland Packing
for Electrical Pump |
nos. |
1 |
|
12 |
Common |
FFS |
Calibration for
1000 GPM Water Flow Meter |
nos. |
1 |
|
13 |
Common |
FFS |
Supply &
Replacement of
Casing Relief
Valve (3/4") |
nos. |
1 |
|
14 |
Common |
CBS |
Supply &
Replacement of
Tube (8W) |
nos. |
35 |
|
15 |
Common |
CBS |
Supply
& Replacement of Exit Light
wallmount (JSB) |
nos. |
9 |
|
16 |
Common |
CBS |
Supply &
Replacement of
Exit Light Hanging (JSB) |
nos. |
3 |
|
17 |
Common |
CBS |
Supply &
Replacement of
Emergency
Light (JSB) |
nos. |
5 |
|
20 |
Block-B |
Pump Room |
FACP |
Supply &
Replacement of
Input Module |
nos. |
1 |
22 |
Common |
FE |
Supply &
Replacement of
Hose for Co2 5 kg Fire
Extinguisher |
nos. |
6 |
|
23 |
Common |
FE |
Refilling
of DCP 4.5 kg Fire
Extinguishers |
nos. |
3 |
|
24 |
Common |
FFS |
Reducer
Cap |
nos. |
1 |
|
25 |
Common |
FFS |
Supply &
Replacement of
Casing Relief
Valve (3/4") |
nos. |
1 |
|
26 |
Common |
FFS |
Supply &
Refilling of Coolant for
Diesel Pump (3 Gallon) |
nos. |
1 |
|
27 |
Common |
FFS |
Supply &
Replacement of
Pressure Gauge 60 PSI |
nos. |
1 |
|
28 |
Common |
CBS |
Supply &
Replacement of
Tube (8W) |
nos. |
25 |
|
29 |
Common |
CBS |
Supply
& Replacement of Exit Light
wallmount (JSB) |
nos. |
15 |
|
30 |
Common |
CBS |
Supply &
Replacement of
Exit Light Hanging (JSB) |
nos. |
7 |
|
31 |
Common |
CBS |
Supply &
Replacement of
Emergency
Light (JSB) |
nos. |
4 |
32 |
Block-C |
5th F Corridor nr store |
FACP |
Supply
& Replacement of Smoke
Detector with Base |
nos. |
1 |
36 |
Common |
FFS |
Supply &
Replacement of
Battery Charger |
nos. |
1 |
|
37 |
Common |
FE |
Supply &
Replacement of
Hose for Co2 5 kg Fire
Extinguisher |
nos. |
7 |
|
38 |
Common |
FOAM |
Supply &
Replacement of
Level tube for Foam |
nos. |
1 |
|
39 |
Common |
CBS |
Supply &
Replacement of
Tube (8W) |
nos. |
32 |
|
40 |
Common |
CBS |
Supply
& Replacement of Exit Light
wallmount (JSB) |
nos. |
13 |
|
41 |
Common |
CBS |
Supply &
Replacement of
Exit Light Hanging (JSB) |
nos. |
3 |
|
42 |
Common |
CBS |
Supply &
Replacement of
Emergency
Light (JSB) |
nos. |
10 |
|
43 |
Common |
FM200 |
Supply &
Replacement of
Battery (12v,
7Ah) for
FM200 Panel |
nos. |
2 |
|
44 |
|
Common |
VES |
Supply
& Replacement of Auxilary
Power supply (APS)
card
for Voice Evacuation Panel |
nos. |
1 |
45 |
|
Common |
VES |
Supply &
Replacement of
Amplifier
Card (AA50)
for Voice Evacuation Panel |
nos. |
1 |
45 |
|
Common |
FACP |
Programming
of FACP |
nos. |
1 |
Terms & Condition

SAGA International

Balqis Residence Jointly Owned Property
Mixed UseBalqis Residence Palm Jumeirah West Crescent, Dubai, United Arab Emirates