Water Tank cleaning and pipeline disinfection

AMC
Posted On: September 17, 2026
Closing On: October 2, 2026
JOB REFERENCE:
JB11974-26-00069

Water Tank Cleaning – Dubai Municipality Compliance (Legionella & Microbiological Control) and pipeline disinfection

From (01/01/2027 to 31/12/2029)

1. Pre-Cleaning Preparation

  • Review and comply with Dubai Municipality (DM) guidelines for water storage and Legionella prevention.
  • Notify building occupants of scheduled cleaning and temporary water supply interruptions.
  • Obtain necessary permits and approvals if required.
  • Conduct risk assessment of tank access, confined space entry, and potential hazards.
  • Ensure all personnel are trained in confined space entry, PPE, and Legionella safety protocols.
  • Isolate the water tank from the distribution system:
    • Close incoming mains and outlets.
    • Ensure backup water supply for essential use.

2. Equipment & Safety Measures

  • Provide and wear appropriate PPE: gloves, goggles, respirators, and protective clothing.
  • Use non-sparking tools for metal tanks and approved disinfectants only.
  • Ensure safety signage and barriers around work area.
  • Prepare equipment: brushes, high-pressure washers, suction pumps, chemical dosing pumps, and sampling kits.

3. Water Tank Draining

  • Drain the entire tank completely.
  • Safely dispose of or recycle residual water according to environmental regulations.
  • Document water volumes and quality before cleaning (if required by DM).

4. Mechanical Cleaning

  • Remove all sediment, sludge, biofilm, and debris from the tank interior.
  • Scrub tank walls, floor, baffles, and roof using approved brushes and high-pressure washing.
  • Pay special attention to corners, inlets, outlets, overflow points, and fittings where biofilm may accumulate.
  • Remove and clean tank ladders, screens, and access covers.

5. Chemical Disinfection

  • Apply DM-approved disinfectant (typically chlorine-based) at the recommended dosage for Legionella and microbiological control.
  • Ensure disinfectant reaches all surfaces including dead legs, pipes, inlets, and outlets.
  • Maintain contact time as per DM or manufacturer guidelines (usually ≥30 minutes).
  • Flush and rinse the tank thoroughly to remove residual disinfectant.

6. Microbiological Testing

  • Collect water samples before and after cleaning for microbiological testing.
    • Parameters: Legionella spp., total coliforms, E. coli, and heterotrophic plate count (HPC).
  • Send samples to a DM-approved accredited laboratory.
  • Ensure results meet DM potable water microbiological standards:
    • Legionella: <100 CFU/100 mL (for public facilities; check latest DM guidelines)
    • Total coliforms: 0 CFU/100 mL
    • E. coli: 0 CFU/100 mL
    • HPC: ≤500 CFU/mL (or as per DM standards)

7. Tank Refilling

  • Refill the tank with DM-approved potable water.
  • Flush all outlets to ensure complete distribution and removal of residual chemicals.
  • Restore normal water supply to the system.

8. Documentation & Reporting

  • Prepare a comprehensive cleaning report, including:
    • Pre-cleaning water quality results
    • Cleaning methodology (mechanical and chemical)
    • Disinfectant type, dosage, and contact time
    • Microbiological test results after cleaning
    • Date, time, and duration of works
    • Personnel and safety records
  • Submit the report to Dubai Municipality if required and maintain a record for regulatory compliance.

9. Optional / Additional Works

  • Installation or inspection of tank access covers and ladders to prevent contamination.
  • Application of tank liners or protective coatings if allowed by DM.
  • Installation of automatic disinfection systems or sensors for continuous monitoring.
  • Periodic maintenance program:
    • Cleaning frequency: at least every 6 months or as per DM risk assessment.
    • Routine microbiological monitoring.
  • Water Tank Cleaning & Disinfecting ( Yearly twice)
  • 1. Domestic Tank – 225m³ | 59400 USG x 1 no. 
  • 2. Fire Tank – 170m³ | 44880 USG x 1 no.
  • 3. GRP Tank – 72m³ | 19008 USG x 1 no. (Partition 8+7 compartments)
  • Pipeline Disinfection  Yearly Twice ,Domestic water pipeline disinfection from supply tank to entire building pipeline networks (G + 16)
  • Laboratory Test TBC+Legionella test will be taken from Domestic tanks on Quarterly basis Total no. of samples 02 x 4 times (Total samples : 08 samples Yearly)
Terms & Condition

Payment terms: 

 

100% with in 30 Days after work completion and sharing the invoice.

APPLY NOW
OSOOL ASSET MANAGEMENT SERVICES L.L.C
OSOOL ASSET MANAGEMENT SERVICES L.L.C
AL GHURAIR RESIDENCE 5
AL GHURAIR RESIDENCE 5
Residential

Plot No. 645-7562 @ Al ghurair Residence 5 Living Legend - Wadi Al Safa 3 - Dubai, Dubai, United Arab Emirates

Share