Fire 3RD Party Inspection / Certification Contract
ContractJOB REFERENCE:
JB007-25-02485
|
Sir. | Equipment’s Name | Trade Name | Quantity | Remarks |
1. | Main Control Panel | G.S.P | 4 | Maintenance |
2. | Smoke Detector | G.S.P | 710 | Maintenance |
3. | Heat Detector | G.S.P | 151 | Maintenance |
4. | Fire pump | Radi Baflo | 1 Set | Maintenance |
5. | Hose Reel | Navco | 73 | Maintenance |
6. | Fire Hoses | Navco | 73 | Maintenance |
7. | Landing Valves | Navco | 73 | Maintenance |
8. | Break Glasses | G.S.P | 78 | Maintenance |
9. | Fire Alarm Bell | Cober | 176 | Maintenance |
10. | Sprinkler System | Central | 2180 | Maintenance |
11. | Wet Riser | Navco | 3 | Maintenance |
12. | FM- 200 | Navco | 2 | Maintenance |
13. | Fire extinguisher ( Powder4.5 KG) | Navco | 124 | Maintenance |
14. | Fire extinguisher (Co2 10 lbs) | Navco | 144 | Maintenance |
15. | Fire extinguisher ( powder 2 KG) | Navco | 2 | Maintenance |
16. | Central Battery system | Cober | 1 | Maintenance |
Scope of service.
The scope of service shall carry out the fire life safety audit inspection and certificate for Marina Whaf1 in order to establish the current status of premises fire Safety in terms of its construction, means of escape, existing fire safety systems installed & their ongoing maintenance and management procedures in place and ensure safety of both the building and occupants in the event of emergency / fire as follows:
A) The service provider shall carryout the audit inspection of Fire and safety systems in the client’s premises in line with the latest requirement of Dubai Civil Defense.
B) The service provider shall check the system performance and provide the finding report and recommended necessary actions to be taken to upgrade the existing fire and life safety systems in the premises in compliance with international standers and latest requirements of Dubai civil defense.
C) The service provider shall provide to the client / premises owner a fire safety approval certificate approved by Dubai civil defense valid for the period of one year after completion of report finding and performance testing of the system.
D) The service provider shall carry out the inspection , checking and certification of existing fire safety system and maintenance specifications as per Dubai civil defense requirements including the following , but not limited to the same:
1. Check and verification of fire system maintenance practices and procedures followed by the maintenance department / contractor :
2. Carry out audit inspection of throughout premises
3. Carry out audit inspection of the existing water and gas based fire protection system
4. Carry out audit inspection of existing fire detection and alarm system and voice evacuation system.
5. Carry out audit inspection of existing emergency and exit lighting emergency.
6. Carry out inspection of existing fire& safety signage and means of escape.
7. Fire proof doors and fire compartments / Zoning
8. Recommendations to upgrade the fire and life safety systems as per the site requirements according to latest international fire safety codes and civil defense regulations.
9. Preparation and submission of report to civil defense and to the client
10. Witness random functional testing of all fire safety systems which carried out by the maintenance contractor during the final inspection to ensure the system integrity.
11. Review maintenance contracts & advise on scope coverage on all fire and safety system and equipment’s
12. Final inspection and issue certificate after completion.