Chilled Water Testing & Treatment Contract (01-01-2026 to 31-12-2026)
ContractJOB REFERENCE:
JB007-25-03280
HORIZON TOWER YEARLY TREATMENT CHEMICALS AND ANALYSIS:
A ‐ CHILLED
WATER CHEMICAL TREATMENT
& ANALYSIS
Sr. No. |
Description |
Req. Quantity |
||
|
Chilled Water
System: No. Of Chiller : 04 Nos. Capacity : 375 TR × 04 Nos.
Total System Volume :
40 m³ (Approx.) |
|
||
|
|
Yearly Maintenance Chemical Quantity (Based
on 2% system
Loss per |
|
|
month |
) |
|||
1. |
Accepta 0029, Nitrite based Corrosion Inhibitor
Packing: 25 kgs/drum |
100 Kgs |
||
2. |
Accepta 2400,
Micro‐Biocide Packing: 25 kgs/drum |
25 Kgs |
||
|
|
|
||
3. |
Onsite Chemical Analysis & service visit for chilled water (Monthly) |
12 Nos. |
||
B ‐ CONDENSER WATER CHEMICAL TREATMENT
& ANALYSIS
Sr. No. |
Description |
Req. Quantity |
|
Cooling
Tower Treatment System:
No. of Cooling Tower : 04 Nos. (2D+3S) (As per Client) Recirculation Rate (each) : 1125 GPM/255.7 m3/Hr Total Recirculation Rate : 511.4 m3/Hr ∆T : 5.5 oC Cycles of concentration : 6 cycles Evaporation rate : 4.56 m³/hr Bleed Off rate : 0.912 m³/hr Makeup rate : 5.472 m³/hr System Volume :
50 m³ (Approx) |
|
|
Yearly Treatment Chemicals (Based on 5,500 hours per year of peak load |
|
operation) |
||
1. |
Accepta 2312‐ Scale & Corrosion Inhibitor Packing: 25 kgs/drum |
425 Kgs |
2. |
Accepta 2814‐ Dispersant Packing: 25
kgs/drum |
125 Kgs |
3. |
Accepta 2400– Micro
biocide I Packing: 25
kgs/drum |
100 Kgs |
4. |
Accepta 2886 – Micro biocide II Packing: 25
kgs/drum |
100 Kgs |
5. |
Onsite Chemical Analysis & service visit
for Condenser water
(Monthly) |
12 Nos. |
SCOPE OF WORK:
1. Analysis will be done and issue the reports as per schedule.
2. Chemicals will be supplied to the site as per the quantity mentioned above.
3. Emergency site visit as and when requested, due to unwanted circumstances regarding the water systems.
4. Training will be provided
to the technicians /operators, on proper handling of the chemicals and basic
operations of the various water systems.
5. Service visit will be done as per schedule with technical recommendation to the site person for any changes.
6. Analysis from Dubai Municipality approved lab for chilled
water and condenser water will be
provided as per schedule.