 NO Description Qty 1. 90-degree carbon steel seamless 12 Inch Elbow Sch 40 20 No’s 2. Seamless carbon steel pipe 12 Inch Sch 40 400 Mtr 3. 12 Inch # 150 class SORF flange 16 No’s 4. 2Inch Ball valve # 150 class with blind flange 4 No,s 5. 2inch seamless pipe Sch 40 12 Mtr 6. 2 Inch SORF FLANGE # 150 8 No’s 7. 12 Inch Blind Flange 2 No’s 8. 12" Butterfly valve 4 No’s 9. Aluminium access door 48No’s

● To make Civil Openings in each floor and two roof slabs for proper access to riser piping. (Establish proper access points and routes for equipment and personnel, considering any height limitations or constraints inside the shaft riser.) ● Removal of existing 12" Ø Vertical Condenser Piping starting from roof up to basement for both towers including small part of horizontal piping in basement ● Ensure that all mobilization and lifting operations comply with relevant safety protocols, including risk assessments for crane use, working at height, and any other specific hazards associated with the shaft riser installation. ● Arrangement of mobile crane to remove old pipes / shift new pipes to roof. (Utilize a crane or any other heavy-lifting equipment to move large or heavy pipes, valves, and materials from ground level to the required floor levels in the towers, particularly for items that need to be transported through the shaft riser.)  
Terms & Condition

No Subcontracting: In accordance to Jointly Owned Property Law No.6,2019, Notwithstanding anything in this Agreement, the vendor/contractor may not use any subcontractor to perform any of his obligations under this work order. Unless: 

(a) Vendor has obtained the prior written consent of SAGA to the use of the subcontractor, and 

(b) Vendor has entered into a separate written agreement with the subcontractor which requires the subcontractor to agree to and abide by all the terms and conditions of this Agreement. 

The Community shall be deemed to be a third-party beneficiary of any such agreement between the vendor and a permitted subcontractor. 

Notwithstanding the foregoing, the vendor shall not be relieved of any of its duties or obligations under this Agreement as a result of entering into a written agreement with a permitted subcontractor.
APPLY NOW
SAGA International Owners Association Management Services LLC
SAGA International Owners Association Management Services LLC
DEC Towers Jointly Owned Property
DEC Towers Jointly Owned Property
Residential

Dec Towers Dubai Marina, Dubai, United Arab Emirates

Share