1. Transfer Pump Repair

  • Inspect the transfer pump body for damage.

  • Repair/replace cracked pump body as required.

  • Rectify leakage and ensure proper sealing.

  • Carry out testing and recommissioning after repair.

2. Valve Rectification

  • Inspect leaking gate valve and carry out necessary repair or replacement.

  • Remove and replace the faulty NRV (Non-Return Valve).

  • Ensure proper installation and leak-free operation.

  • Test valve performance under operating conditions.

3. Chilled Water Pump-01 (MVT/CHWP1B) Servicing

  • Carry out complete servicing of Chilled Water Pump-01.

  • Inspect motor condition due to reported burning smell.

  • Check bearings, coupling, alignment, and electrical connections.

  • Replace defective components if required.

  • Perform testing, trial run, and recommission the pump.

4. Testing & Handover

  • Conduct final inspection and operational testing.

  • Confirm leak-free operation and system performance.

  • Submit service report and completion handover.

5. Warranty

  • Provide 6 months warranty 

Terms & Condition

The Supplier certifies that to the best of his knowledge and belief no economic, beneficial, or managerial relationship exists between the Supplier and any employee of Itihad Community Management (ICM) or between Supplier  and any relative of an employee of ICM or any of its agents, which would tend in any way to influence such employee in performance of his or her duties on behalf of ICM or its agents in connection with the awarding, making, amending, or making a determination concerning performance of its proposal the work or the agreement.

Exchanges or offering of any money, gift item, personal service, entertainment or unusual hospitality by the Supplier to the employees or agents is expressly prohibited. This prohibition is equally applicable to officers, employees, or immediate family members of ICM’s agents. Any violation of this provision constitutes a material breach of ICM’s terms of agreements.  

ICM may by written notice to the Supplier disqualify and reject the Supplier’s proposal and terminate the agreement without any liability whatsoever on part of ICM or any of its agents if finding (a) that vendor violated the certification contained in this declaration regarding conflict of interest; or (b) that gratuities were offered or given by the Supplier or any of its employees , agents or representatives, to any officers or employees of ICM or its agents awarding making and/or amending an RFP document or agreement or securing favorable treatment with respect to the performance of such agreement. 

Itihad Community Management is not under any obligation to accept the lowest or any proposal.

 

The timeline for the elevator modernization work is as follows:

  • Manufacturing: 20 weeks
  • Shipping: 6 weeks
  • Execution: 10 months for all lifts

In the event that the Management determines the work is experiencing delays, it reserves the right to impose penalties on the Service Provider.

APPLY NOW
ITIHAD COMMUNITY MANAGEMENT
ITIHAD COMMUNITY MANAGEMENT
Marina View Towers
Marina View Towers
Residential

Marina VIew Tower, Dubai Marina, Dubai, UAE, Dubai, United Arab Emirates

Share