Firefighting & Fire Alarm System Rectification

Services
Posted On: October 24, 2024
Closing On: November 24, 2024
JOB REFERENCE:
JB007-24-03050
Firefighting & Fire Alarm System Rectification

Fire System: GST Brand
FACP: FIREX

S.No DescriptionQty
        FIRE ALARM SYSTEM
1Replacement of Smoke detector with base12 No's 
2Replacement of Sounder control module1 No
3Replacement of Single input module1 No
4Replacement of Speaker ceiling type brand: Bosch2 No
5Replacement of Heat detector 5 No's 
6Replacement of Metal Column Speaker1 No
7Replacement of Sounder base4 No's 
8Supply of Smoke detector with base (spare)20 No's 
9Supply of Heat detector with base (spare)20 No's 
10Supply of Sounder (spare)10 No's 
        FIRE FIGHTING SYSTEM
11Replacement of Landing valve hose2 No's 
12Replacement of Landing valve cup1 No 
13Replacement of 1" Gate valve26 No's
14Replacement of Fire hose reel nozzle loc: 12th floor lift lobby1 No
15Replacement of 6" Butterfly valve1 No 
16Replacement of manual fire hose reel6 No's 
        FIRE PUMP
17Replacement of Pressure switch 16 bar1 No
18Suction line leak rectification by replacing 6"Pipes, fittings and necessary accessories including welding1 No
19Landing valve socket leakage rectification 2 No's 
20Replacement of Diesel tank hose1 No
21Replacement of Level tube 1 No
        FIRE EXTINGUISHERS
22Refilling DCP 12kg2 No's 
23Replacement of Co2 5 lbs horn6 No's
24Replacement of Co2 5Kg horn4 No's
25Supply & Fixing Co2 5kg loc: telephone room44 No's 
26Supply & Fixing DCP 4KG LOC: Gym and Swimming pool area 5 No's 
27Supply & Fixing CO2 5KG LOC: Gym and Swimming pool area 5 No's

Community Details

Building Name: Horizon Tower

Location: Marsa Street, Dubai Marina

Site Contact: Mr. Ramana (Facilities Engineer) - 050 272 5615

Terms & Condition

No Subcontracting: In accordance to Jointly Owned Property Law No.6,2019, Notwithstanding anything in this Agreement, the vendor/contractor may not use any subcontractor to perform any of his obligations under this work order. Unless: 

(a) Vendor has obtained the prior written consent of SAGA to the use of the subcontractor, and 

(b) Vendor has entered into a separate written agreement with the subcontractor which requires the subcontractor to agree to and abide by all the terms and conditions of this Agreement. 

The Community shall be deemed to be a third-party beneficiary of any such agreement between the vendor and a permitted subcontractor. 

Notwithstanding the foregoing, the vendor shall not be relieved of any of its duties or obligations under this Agreement as a result of entering into a written agreement with a permitted subcontractor.

As per standards
APPLY NOW
SAGA International
SAGA International
Horizon Tower Jointly Owned Property
Horizon Tower Jointly Owned Property
Residential

Horizon Tower Dubai Marina, Dubai, United Arab Emirates

Share