Search Jobs
Annual Maintenance Contract for MEP & Cleaning Services - 2026 (JB004-26-00748)
Contract
Mixed Use
The Community, Jumeirah Village Triangle, Dubai, United Arab Emirates
Posted By: HOAM- Highrise Owners Association Management
Annual Maintenance Contract for MEP & Cleaning ServicesManpower DeploymentFacility Engineer / Supervisor – 1day (Full Time)HVAC Technician – 1no (Full Time). Multi Technician – 1 No. (Day Shift)Electrical technician - 1day/1night. Cleaning TeamCleaners – 4 Nos. (Day Shift including)Cleaners – 1 No. (Night Shift)...
Swimming Pool Equipment's Rectification Work - O10 (JB004-26-00738)
Break Down
Residential
Al Jaddaf - Dubai Healthcare City, Dubai, United Arab Emirates
Posted By: HOAM- Highrise Owners Association Management
SL NoDescriptionUnitQty1Repair of 2.52kW Filter Pump (Astral) – Replacement of 2 Bearings, Mechanical Seal, Pump Body & TestingNos12Supply & Installation of 2.52kW Filter Pump (Astral) with necessary Plumbing & Electrical WorksNos13Supply & Replacement of 2” Gate Valve – Filter Pump Suction LineNos24Supply &am...
Break Down
Mixed Use
JLT, Dubai, United Arab Emirates
Posted By: HOAM- Highrise Owners Association Management
Rooftop Logo – Light Rectification Works
Logo Dimensions: 3564 × 5000 mm (2 sets)
Scope of Work:Logo Dimensions: 3564 × 5000 mm -2 sets
Removal of existing defective LED modules and power supply units from both rooftop logos.
Supply and installation of new Samsung waterproof LED modules.
Supply and installation of ...
Supply and Replacement of BMS Equipment's - GCV (JB004-26-00662)
Break Down
Mixed Use
Goldcrest Views, Jumeirah Lakes Towers, Dubai, United Arab Emirates
Posted By: HOAM- Highrise Owners Association Management
FCU Controller – Honeywell W7754 - 2 Nos.Power Supply : 230 Vac +10%, -15%, 50/60 HzHardware Design : Processor: Neuron 3150® running at 5 MHz, with 2 kBof RAM and 0.5 kB of EEPROM on chip.Ext. memory: EPROM, 64 kB by 8.Specified Sensing Temperature Range : 32° to 104°F (0° to 40°C)Environmental Ratings : Operating temperatur...
Rectification of booster Pump Headers and Accessories (JB004-26-00636)
Break Down
Residential
La Vista Residence 3, Dubai Silicon Oasis, Dubai, United Arab Emirates
Posted By: HOAM- Highrise Owners Association Management
Rectification of booster Pump Headers and Accessories • Replacement of booster pump inlet and outlet headers. • Replacement of rusted inlet and outlet pipeline sections. • Replacement of existing gate valves with new corrosion-resistant valves. • Replacement of flexible unions to ensure vibration isolation...
Repairing & Servicing of Sum Pump (JB004-26-00626)
Break Down
Residential
The Diamond Tower, Dubai Sports City, Dubai, United Arab Emirates
Posted By: HOAM- Highrise Owners Association Management
Repairing & Servicing of 2.2Kw KSB ARAMAX Submersible Pump (QTY: 02) Basement B-2Removal & Collection – Existing pump removal and transportation from site to workshop 1. Stripping & Dismantling – Pump breakdown into basic components at workshop 2. Motor Stator Re-winding – Class F insul...
Rectification of Transfer Pump (JB004-26-00589)
Break Down
Mixed Use
Atlantic Tower, Dubai Marina, Dubai, United Arab Emirates
Posted By: HOAM- Highrise Owners Association Management
Rectification of Transfer PumpThe transfer pump is failing to transfer water and is producing unusual noise. Upon
inspection, bearing problems were identified. Transfer Pump Repairing Remove and collect the Pump from site Stripping of pump into basic parts Supply and fix both side Motor Bearing Suppl...
2 no’s Sump Pumps Need to Repair or Replaced (JB004-26-00570)
Break Down
Mixed Use
Atlantic Tower, Dubai Marina, Dubai, United Arab Emirates
Posted By: HOAM- Highrise Owners Association Management
2 no’s Sump Pumps Need to Repair or ReplacedAt the Atlantic Building basement parking area, both sump pumps were found to be non-operational due to motor winding defects. Additionally, one pump has a damaged discharge pipe. These sump pumps are responsible for conveying wastewater. Therefore, their failure pose...
Break Down
Mixed Use
Dubai Marina, Dubai, United Arab Emirates
Posted By: HOAM- Highrise Owners Association Management
Scope of
Work
PRV 2inch -
382mFO-SP-50-FL/FL-50/50 PN16 EPDM Installation. Supply & installation of
Butterfly valve with necessary flanges & fittings accessories. Carryout
installation of PRV with accessories. Carryout necessary PPR works. – 2 Nos
Mechanical Electrical Plumbing (MEP) Break Down (JB1099-26-00659)
Break Down
Mixed Use
Dubai Marina, Dubai, United Arab Emirates
Posted By: SG Community Management Services LLC
Dear
Service Provider,
Greetings
from Strata Global!
Kindly
arrange a site visit and send us your best proposal for Application of Fire
Rated silicon in Chilled water pipeline sleeves in Marina Arcade, located
in Dubai Marina, Dubai.
Scope
of Work:
Application of Fire Rated silicon in Chilled wat...
Swimming pool heat/cool system (JB004-26-00500)
Break Down
Mixed Use
Dubai Marina, Dubai, United Arab Emirates
Posted By: HOAM- Highrise Owners Association Management
Additional NotesProvide and install new Reversible Cycle Heat Pumpo Heating output: 90 kWo Cooling output: 70 kWo 380V / Three Phase / 50 Hzo Titanium heat exchangero Scroll compressorProvide and install new Big Discovery self-primary pumpo 3.0 HPo Three phasesDismantle and remove existing faulty heat/cool pump unito Safe rem...
Gate Valve Leakage at B-1 Parking (JB004-26-00467)
Break Down
Residential
The Spirit, Dubai Sports City, Dubai, United Arab Emirates
Posted By: HOAM- Highrise Owners Association Management
Supply & installation of:2-inch Gate Valve Brass 1 QTY2-inch Male Adapter HPVC 2 QTYTeflon Tape – 10 nos 10 QTYTangent Solvent Glue 2 QTYClose the DEWA line gate valve by repairing or replacing the faulty components to ensure complete shut-off. Test the valve operation to confirm that water flow can be fully stopped. Once...
Break Down
Residential
La Vista Residence 2, Dubai Silicon Oasis, Dubai, United Arab Emirates
Posted By: HOAM- Highrise Owners Association Management
Scope of Work:Supply and install:1. Staircase Pressurization Fan Motor▪ 415V, 3-phase, 50Hz▪ Fire-rated duty, Insulation Class F/H▪ IP55 rating2. Smoke Extract Fan Motor▪ High-temperature rated (e.g., 250°C/2hr)Insulation Class H▪ 415V, 3-phase▪ IP55 or higher Testing and Commissioning:• Electrical termination, earthing,...
RECTIFICATION OF HOT WATER LEAKAGE (JB004-26-00227)
Break Down
Residential
The Diamond Tower, Dubai Sports City, Dubai, United Arab Emirates
Posted By: HOAM- Highrise Owners Association Management
Scope of Work – Hot Water Leak Rectification
Replacement of faulty gate valve and associated pipes in front of Apartment 1005.
Replacement of faulty PPR pipe, gate valve, and fittings, including ceiling repair and painting, in front of Apartment 609.
Replacement of PPR pipe and fittings in front of Apartment 209.
Apar...